Why can’t I see any bands of bound proteins?
Since the amount of ligand immobilization may be small, consider increasing the immobilization concentration. The affinity between the ligand and the target protein may be weak, so try lowering the salt concentration in the buffer.
Also, if the target protein is low in the protein solution, you may need to consider increasing the concentration or volume of the protein solution.